- 3lbs - Portable with a battery backup
- 5" Touch Screen making the CLEO easy and intuitive for any user.
- Long-life lithium-ion battery.
- Suited for bedside and mobile spot check use.
- Respiration and pleth waveform.
- The CO2 uses a 50/ml per minute sidestream method to deliver the most accurate EtCO2 readings.
- Used on both intubated and non-intubated patients.
- The sample line connection system uses filter cells to eliminate the potential for cross-contamination.
Product Specifications
| Manufacturer Part 000.500.0003: | SpO2 Only with Adult Finger Sensor Option |
|---|---|
| Manufacturer Part 000.500.0013: | NIBP, SpO2, Heart Rate & Filac 3000 Thermometer Option |
| Manufacturer Part 000.500.0005: | NIBP, SpO2 & Heart Rate Option |
| Manufacturer Part 000.500.0013: | NIBP, SpO2, Heart Rate & Filac 300 Thermometer Option |
| Manufacturer Part 000.500.0004: | CO2 and SpO2 with Accessories Option |
| Manufacturer Part 000.500.0001: | SpO2, NIBP & Heart Monitor Option |
| Manufacturer Part 000.500.0000: | CO2 Only with Accessories Option |
| Base Unit Dimensions: | 8" x 4.5" x 4" |
| Weight: | 2.5 lbs |
| Display: | 5" (Diagonal) Color TFT |
| Resolution: | 800 × 3 (RGB) × 480 |
| Trace: | 2 Waveforms |
| Waveforms: | PLETH, ETCO2 |
| Indicator: | Alarm Indicator / Power indicator / Pulse beep and alarm sound |
| Trend time: | From 1 to 72 hours |
| NIBP Measuring Technology: | Automatic Oscillating Measurement |
| NIBP Cuff Inflating: | <30s (0 - 300 mmH, standard adult cuff) |
| NIBP Measuring Period: | AVE<40s |
| NIBP Mode: | Manual, Auto, STAT |
| NIBP Measuring Interval in AUTO Mode: | 2 min - 4 hrs |
| NIBP Pulse Rate Range: | 30 bpm - 250 bpm |
| NIBP Measuring Range: | SYS 40 - 250 (mmHg) / DIA 15 - 200 (mmHg) |
| NIBP Resolution: | 1mmHg |
| NIBP Pressure Accuracy: | Maimum Mean Error +5mmHg |
| NIBP Maximum Standard Deviation: | 8mmHg |
| NIBP Overpressure Protection: | Adult Mode 280 (mmHg) |
| NIBP Alarm Limit: | SYS 50 - 240 mmHg / Dia 15 - 180 mmHg |
| NIBP Standards: | Meets performance standards of ANSI/AAMI SP10 |
| ASpO2: | Anti-motion SpO2 |
| SpO2% Range: | 0 ~ 100% |
|---|---|
| SpO2 Accuracy: | ±2% (70 ~ 100%,non-motion) / ±3% (70 ~ 100%, motion) |
| Pulse Rate Range: | 30-250 bpm |
| Pulse Rate Accuracy: | ±2 bpm(non-motion) / ±3 bpm (motion) |
| Alarm Upper-lower Limit: | Upper limit 70 ~ 100% / Lower limit 70 ~ 100% |
| SpO2 Probe: | Red light LED wavelength 660nm±5nm / Infrared light LED wavelength 940nm±10nm |
| Standards: | Meets performance standards of EN ISO 9919 |
| Mode of Sampling: | Sidestream or Mainstream |
| Principle of Operation: | Non-dispersive infrared (NDIR) single beam optics, dual-wavelength, no moving parts |
| CO2 Measurement Range: | 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa) |
| CO2 Calculation Method: | BTPS (Body Temperature Pressure Saturated) |
| CO2 Resolution: | 0.1mmHg (0-69mmHg) / 0.25mmHg (70-150mmHg) |
| CO2 Accuracy: | 0 ~ 40 mmHg ± 2 mmHg / 41 ~ 70 mmHg ± 5% of reading / 71 ~ 100 mmHg ± 8% of reading / 101 ~ 150 mmHg ± 10% of reading/ Above 80 breaths per minute ± 12% of reading |
| Sampling rate: | 100Hz |
| Respiration Rate: | 2 ~ 150 bpm |
| Respiration Rate Accuracy: | ±1 breath |
| Response Time: | <3 seconds - includes transport time and rise time |
| Inspired CO2 Measurement Range: | 3 ~ 50 mmHg |
| Standards: | Meets performance standards of ISO/FDIS 21647 |
| Power Source: | External, AC Power, or Internal Battery |
| AC Power: | 100 - 240VAC, 50/60Hz, 150VA |
| Battery: | Built-in and lithium Ion rechargeable, 12.6V/5AH |
| Charge Time: | 8 Hours |
| Operating Time: | 3 Hours |
| Operating Temperature: | 5 ~ 40 °C |
| Storage Temperature: | -20 ~ 60 °C |
| Operating Humidity Range: | <80% |
| Storage Humidity Range: | <80% |